Reload panel modules from outside the session: control socket, chandra-ctl, SIGUSR1
CI / test (push) Failing after 16s
CI / test (push) Failing after 16s
Until now a module reload was only reachable by clicking Settings > Panel inside the session. Now: - The compositor listens on $XDG_RUNTIME_DIR/chandra/<wayland socket name>.sock (the login session's is wayland-moon-0.sock) with a line protocol: ping, list, reload [NAME], help. Replies end with an "ok ..." or "error ..." line. It lives in compositor/host/control.mbt, runs from ChandraCompositor::step, and its fds join the idle loop's wait set, so an idle desktop still sleeps (measured ~0.4% CPU on wasmhost, ~0.1% on host-wasm) and wakes for a command. A path another live compositor answers on is left alone. - DesktopShell::reload_modules(name) reloads every loaded module (or those whose module id, stem, slot or path is NAME) in place via replace_slot: same panel position, saved :module-config applied, a module that fails to load stays as it was and the error is reported to the caller and shown as a notice. The catalog is rescanned. - SIGUSR1 to the host reloads every module (result in the log and the notice): new WIT function sys.take-sigusr1, implemented in compositor/sys (native build and wasmhost) and host-wasm; the handler has no SA_RESTART so it interrupts the idle poll. - session/chandra-ctl (installed to /usr/local/bin), `just reload [NAME]`, docs/reloading.md, README. - Tests: compositor/host/control_test.mbt (protocol, reload all / by name / by slot, order and settings kept, failing module kept, busy socket). Checked headless on both hosts with chandra-ctl and kill -USR1. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01DPL5hjLJtvYcgW48okL6qQ
This commit is contained in:
21 files changed
+844
-31
No files matched your search
@@ -110,6 +110,10 @@ install-session-rust: compositor-wasm host-wasm modules
|
||||
install-session-native: build-release modules
|
||||
scripts/as-root python3 "{{justfile_directory()}}/session/install.py" --native
|
||||
|
||||
# Reload the running session's panel modules from disk (after install-session or `just modules`), keeping their order and settings. `just reload clock-digital` reloads one. See docs/reloading.md.
|
||||
reload *name:
|
||||
python3 session/chandra-ctl reload {{name}}
|
||||
|
||||
# Remove the login session again.
|
||||
uninstall-session:
|
||||
scripts/as-root python3 "{{justfile_directory()}}/session/install.py" --remove
|
||||
|
||||
Reference in new issue
Block a user