Add live peak meters (pavucontrol-style level bars)
Each row on Playback, Output Devices and Input Devices gets a level bar under its slider. A meter is a small capture pw_stream on WirePlumber's pw_core with the properties pipewire-pulse gives pavucontrol's peak streams (stream.monitor, target.object, stream.capture.sink for sinks); its process callback folds samples into a peak that a 40 ms GUI timer reads, maps with the slider's cubic curve and decays smoothly. - Only the visible tab is metered; output/stream meters are passive. - stream.monitor nodes (ours and pavucontrol's) are hidden from the tabs. - moonmix-probe gains `meter <id>`; the smoke test now plays noise and checks the stream and sink meters see it. - Screenshot mode holds the meters still before capturing, since a constantly redrawing window never yields a frame under broadway. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
1 parent
92ae5cdbfe
commit
f08f241edb
17 files changed
+503
-18
No files matched your search
@@ -103,6 +103,18 @@ extern "C" fn ffi_set_default(kind : Int32, id : Int32) -> Int32 = "mm_wp_set_de
|
||||
///|
|
||||
extern "C" fn ffi_move_stream(stream : Int32, device : Int32) -> Int32 = "mm_wp_move_stream"
|
||||
|
||||
///|
|
||||
extern "C" fn ffi_meter_start(id : Int32, kind : Int32) -> Int32 = "mm_wp_meter_start"
|
||||
|
||||
///|
|
||||
extern "C" fn ffi_meter_stop(id : Int32) = "mm_wp_meter_stop"
|
||||
|
||||
///|
|
||||
extern "C" fn ffi_meter_stop_all() = "mm_wp_meter_stop_all"
|
||||
|
||||
///|
|
||||
extern "C" fn ffi_meter_take(id : Int32) -> Double = "mm_wp_meter_take"
|
||||
|
||||
///|
|
||||
/// NUL-terminated UTF-8 for C.
|
||||
fn cstr(s : String) -> Bytes {
|
||||
@@ -158,7 +170,9 @@ pub fn node_prop(id : Int32, key : String) -> String {
|
||||
///|
|
||||
/// Current state of a node as a model node, or None if it is gone.
|
||||
pub fn read_node(id : Int32) -> @model.Node? {
|
||||
if ffi_node_exists(id) == 0 {
|
||||
// Peak-meter streams (ours, pavucontrol's via pipewire-pulse) are not
|
||||
// something to show or control.
|
||||
if ffi_node_exists(id) == 0 || node_prop(id, "stream.monitor") == "true" {
|
||||
return None
|
||||
}
|
||||
let nch = ffi_query_volume(id)
|
||||
@@ -264,3 +278,38 @@ pub fn set_default_source(id : Int32) -> Bool {
|
||||
pub fn move_stream(stream_id : Int32, device_id : Int32) -> Bool {
|
||||
ffi_move_stream(stream_id, device_id) != 0
|
||||
}
|
||||
|
||||
///|
|
||||
/// Start a live peak meter on a sink, source or playback stream (other
|
||||
/// kinds have nothing to meter). True if one is running for `id`.
|
||||
pub fn meter_start(id : Int32, kind : @model.NodeKind) -> Bool {
|
||||
let k = match kind {
|
||||
Sink => 0
|
||||
Source => 1
|
||||
PlaybackStream => 2
|
||||
RecordStream | Other => return false
|
||||
}
|
||||
ffi_meter_start(id, k) != 0
|
||||
}
|
||||
|
||||
///|
|
||||
pub fn meter_stop(id : Int32) -> Unit {
|
||||
ffi_meter_stop(id)
|
||||
}
|
||||
|
||||
///|
|
||||
pub fn meter_stop_all() -> Unit {
|
||||
ffi_meter_stop_all()
|
||||
}
|
||||
|
||||
///|
|
||||
/// Linear peak (0..1, may exceed 1 when clipping) since the last call, or
|
||||
/// None if `id` has no meter.
|
||||
pub fn meter_take(id : Int32) -> Double? {
|
||||
let p = ffi_meter_take(id)
|
||||
if p < 0.0 {
|
||||
None
|
||||
} else {
|
||||
Some(p)
|
||||
}
|
||||
}
|
||||
Reference in new issue