Each row on Playback, Output Devices and Input Devices gets a level bar under its slider. A meter is a small capture pw_stream on WirePlumber's pw_core with the properties pipewire-pulse gives pavucontrol's peak streams (stream.monitor, target.object, stream.capture.sink for sinks); its process callback folds samples into a peak that a 40 ms GUI timer reads, maps with the slider's cubic curve and decays smoothly. - Only the visible tab is metered; output/stream meters are passive. - stream.monitor nodes (ours and pavucontrol's) are hidden from the tabs. - moonmix-probe gains `meter <id>`; the smoke test now plays noise and checks the stream and sink meters see it. - Screenshot mode holds the meters still before capturing, since a constantly redrawing window never yields a frame under broadway. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>