Co-Authored-By: Claude Sonnet 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01DPL5hjq2YbDd5zJXXKWqSR
1.9 KiB
Picking up a new build in a running session
After just install-session the files under /usr/local are new, but the running session keeps
what it loaded at startup. What can be swapped without logging out:
| Part | Reload without logout? | How |
|---|---|---|
Panel modules (/usr/local/share/chandra/modules/*.wasm) |
yes | Settings → Panel: remove the module, add it again |
compositor.wasm (shell, WM, portal backend) |
no | restart the session |
chandra-host (wasmhost) |
no | restart the session |
config/, themes, assets |
not checked | restart the session to be sure |
Panel modules
Modules are loaded by path. The shell's load_path reads the .wasm from disk each time, and
the host's plasmoids load/unload instantiate and drop it (wasmhost/bin/plasmoids.mbt).
A module asks for this through the LoadModule and UnloadInstance requests, handled in
DesktopShell::process_requests (compositor/shell/widgets.mbt). Settings → Panel (the module
selector, with reordering) and the "Add widget" file chooser are the UI for it. The loaded set and
its order are kept in ~/.config/chandra/panel.edn.
So after reinstalling, a module that changed is picked up by unloading and loading it again. A module that imports no new host capability needs nothing else.
Not reloadable
chandra-host and compositor.wasm are read once when chandra-session starts them. There is no
signal handler, reload request or file watcher for them. docs/ARCHITECTURE.md says so
("no hot reload on file change"), and the WM hot-swap in docs/compositor-design.md (replaying
list<window-state> into a new WM component's sync-windows) is a design: nothing triggers it
yet. Changes to the compositor, WM, portal backend or host need a new session: log out and back
in.
Status
Written from reading the code, not from a run: the Panel reload path has not been exercised against an installed build. Correct this page if it behaves differently.